Key Features
PCME STACKFLOW 200 Sensor
- Certified to EN 15267-3 with QAL1 as defined by EN 14181 to EN 16911-2
- Flue gas velocity, temperature and pressure monitoring from a single sensor
- Single stack mount installation provides ease of installation
- Inbuilt manual zero and span checks
- Corrosion resistance coated sensor option
- Automatic inlet-cleaning cycle to reduce maintenance requirements
- High pressure back purge option for increased dust concentrations
- Standalone or PCME network connectivity
- Optional sensor lengths: 0.6, 1.0 and 1.5m to suit various stack diameters and stack connection lengths
PCME STACKFLOW 200 Controllers
- Graphical display and recording of velocity, temperature, flow rate and QAL3 results and trends
- Mass emission calculations
- Secure emissions reporting and QAL3 analysis via the use of PC-ME Dust Tools
- Sensor set-up and configuration capability
- Easy integration with dust monitors for mass emission calculation and reporting
- Industrial communications (Ethernet, Modbus, 4-2mA output/input, alarm relays, output/input)
- Multilingual, menu-driven display and inbuilt data logging for recording measured values and internal diagnostic parameters
Performance
- Approvals: QAL1 Approved to EN 16911-2 by TUV/MCERTS
- Gas velocity: 3-50 m/s (extended Certification Range)
- Minimum detection velocity: 2 m/s
- Measurement type: ProPitot™ (Averaging Pitot technology)
- Active measurement length: 0.5 - 1.5m
- Stack diameter: 0.45 - 5m
- Stack pressure: 600 - 1100 mbar
- Stack temperature: -20°C - 500°C
- Ambient temperature: -20°C - 50°C
Typical Applications
Stack velocity, volumetric flow and pollutant mass release calculations achievable when linked to gas and dust CEMS in the following applications:
- Waste to Energy and Incineration Plant
- Emissions from Steel, Chemical and Mineral processing applications
- Gas Turbines and Coal-fired power plant
- Industrial stacks (before or after final arrestment plant)Variable speed fans on dust arrestment plant